100A/40A Double Pulse Encoder Spot Welder Welding Machine Current Control Time

724,00 kr
+ 83,49 kr Leverans

100A/40A Double Pulse Encoder Spot Welder Welding Machine Current Control Time

  • Märke: Unbranded
Säljs av:

100A/40A Double Pulse Encoder Spot Welder Welding Machine Current Control Time

  • Märke: Unbranded
Rekommenderat återförsäljningspris: 899,00 kr
Pris: 724,00 kr
Du sparar: 175,00 kr (19%)
Säljs av:
724,00 kr
+ 83,49 kr Leverans

I lager

Vi erbjuder följande betalsätt

Beskrivning

Function:OOTDTY1: welding pulse for single and double pulse can be switched to use, each single welding time is set to 0, can become single pulse welding2: with voltage compensation, according to the changes of electricity, automatically adjust the output to ensure that the same parameters in welding with the same heat to keep the same, Solder joint3: parameter adjustment for encoder input mode, more accurate and convenient4: with welding counting function, counting range 0-999, so you do welding "heart" and can be saved.5: timing input 0-100 cycles, unit cycle (1 cycle is 20ms) current input (300-999). The current regulation stage is 0.1%, and the regulation is more divided. If other ranges are required, you can customize them.6:3 blue 0.56 inch digital tube-shaped, browser size than the control knob version large, our knob tube-shaped digital knob is 0.36 inch es.7: on-board power, pedal, trigger, gear, time, current, interval, time, current indicator, so that each state has a clear indication8: the whole board using STM8 industrial microcontroller make the main core control board9: Strong and weak by optocoupler isolation, operation safer.10: power cord and foot switch with screwless clamp, more convenient and reliable11: design a reliable zero passage detection circuit to ensure the accuracy of SCR12: the controller is compatible with 100A-40A thyristorDescription:1. This controller has 3 kinds of working condition, welding preparation, parameter query, parameter change2. Preparation for welding: the running light is always on, time, current, interval, time, current indicator is off3. Parameter query: start indicator off, time, current, interval, time, current corresponding to the indicator, the digital tube-shaped is always on, the displayed value is the corresponding parameter value4. Parameter change: the working indicator is off, the time, current, interval, time and current correspond to the indicator, and the LED flashes. The displayed value is the corresponding value for changing the parameter value.5. Preparing for WeldingSelecting/adjusting the encoder counterclockwise, the running light is on, the time, current, interval, time and current indicator are off. Welding can be done during this time. The value displayed by the digital tube shape is the current welding counting value.6. Voltage CalibrationSince this controller is equipped with a voltage compensation function, voltage calibration is required when the machine is first installed and only one calibration is required. (Unless you are replacing the power transformer, you do not need to calibrate)7. Calibration operation: In the working state, press and hold for one minute to open until the time, current and interval light up. During this time, use a multimeter to measure the mains voltage. For example, when the measured voltage is 225V, rotate the encoder to get a digital tube-shaped. The displayed value is 225, then double-click the micro switch to exit calibration.8. Parameter changesDuring the parameter check, the encoder is rotated by [select/adjustment] and a query is performed. When the indicator light is on, the digital tube-shaped displays the parameter values of the current corresponding parameters.A. Select/ajust rotate clockwise until the interval light is lit and the digital display value is the current time intervalB. Enter/SaveClick to enter parameter settings, digital tube-shaped flashes To. Select/Ajust rotate, change parameters, increase clockwise, decrease counterclockwiseD. Enter/SaveClick to save the parameters, the digital tube-shaped stops flashing. Select/Ajust rotate counterclockwise until the upward running lights, enter the welding preparation state, change the parametersFor example: rotate [select/adjust], set the interval indicator, and then the value displayed by the digital tube-shaped is the interval time9. Counting alreadyThe controller is equipped with welding counting function. In a welding operation, the number of welds is automatically increased by 1 for each weld. Counting range 0-999.If you want to clear, in the working state, double click the [Enter/Save] button, the number will be cleared automatically. Package Included:1x Dual Encoder Pulse Timing Controller
  • Fruugo-ID: 399836095-851090530
  • EAN: 6935170347232

Produktsäkerhetsinformation

Se produktsäkerhetsinformationen som är specifik för denna produkt som beskrivs nedan

Följande information tillhandahålls av den oberoende tredjepartsåterförsäljaren som säljer denna produkt.

Tillverkarens artikelnummer: 6935170347232

Leverans och returer

Skickas inom 24 timmar

  • STANDARD: 83,49 kr - Leverans mellan kl tors 16 oktober 2025–tis 28 oktober 2025

Leverans från Kina.

Vi gör vårt bästa för att säkerställa att produkterna du beställer levereras kompletta och enligt dina specifikationer. Om du däremot skulle ta emot en ofullständig beställning, eller andra artiklar än de du beställt, eller om det finns någon annan anledning till att du inte är nöjd med din beställning, kan du returnera beställningen, eller valfria produkter som ingår i beställningen, och få fullständig ersättning för artiklarna. Visa fullständig returpolicy