Digital LCD Flow Meter Indicator for Diesel, Gasoline, Oil, and Methanol Fuels

499,00 kr
gratis leverans

Digital LCD Flow Meter Indicator for Diesel, Gasoline, Oil, and Methanol Fuels

  • Märke: Unbranded
Säljs av:

Digital LCD Flow Meter Indicator for Diesel, Gasoline, Oil, and Methanol Fuels

  • Märke: Unbranded
Rekommenderat återförsäljningspris: 674,00 kr
Pris: 499,00 kr
Du sparar: 175,00 kr (25%)
Säljs av:
499,00 kr
gratis leverans

I lager

Vi erbjuder följande betalsätt

Beskrivning

Item Type: Flow MeterMaterial: ABSStandard: VerticalMedia: Methanol, diesel fuel, kerosene, chemical liquid, urea waterImporters: 1in internal threadMeasurement Accuracy: 1%Repeatability: 0.5%Maximum Working Pressure: 20BAROperating Voltage: 2.3 - 3.3VStandby Time: 2 YearsFlow Range: 10 - 120L / MINSingle Count: 0.00 - 999.9Total Cumulative Number: 0.00 - 999999.9Unit: L / L, gal / GAL, pint / PTS, quart / QTSSingle Measurement Cleared: RESETBattery: Built-in battery, 2 x AAA batteries, 500mAh(include batteries)Setting Units of Measurement:1. In the standby mode, or raise the amount of current display state2. Press CAL + RESET button for 5 seconds3. Enter unit conversion settings, press the RESET button4. Followed by LTR - GAL - PT -QT - LTR choose the unit of measurement5 .While the cumulative filling volume displayed in the current unit of measure conversion after6. Press the MENU key for 3 seconds to exit the unit conversion settings.Operating Instructions1. Measuring Unit SettingUnder standby state or current amount display state, press and hold MENU+RESET buttons for 5 seconds to enter unit conversion setting, then press RESET button to select unit in turn of LTR - GAL - PT - QT - LTR. Press and hold MENU button for 3 seconds to exit unit conversion setting.2. Accumulative and Current Amount ResetPress and hold RESET button and LCD screen displays on full screen, wait till the full screen display end then loose the RESET button. At this time the accumulative amount and current amount is reset.3. Error Coefficient and Accumulative Amount InquireUnder standby state, press MENU + RESET button together, then LCD display shows the error coefficient on the upper row, and accumulative amount on the lower row.4. Error Coefficient CalibrationUnder standby state or current amount display state, press and hold MENU button for 3 seconds to enter error coefficient calibration mode. The first digit flashes, press MENU button to change position of the digit, and press RESET button to change digit. As this coefficient increases, output oil quantity reduces. Then press and hold MENU button for 3 seconds to end error coefficient calibration and return to current amount display state, and the current amount is reset as zero. The calibration error coefficient range is 0.1000 to 9.9999. For example, original coefficient is 1.000, when it displays 100 liters output of oil, the actual oil output is 100L. If you need 2 liter reduced, set the coefficient as 1.020, then the output would be 98L.5. MaintenanceWhen battery voltage is too low, a battery symbol appears on the LCD display, which reminds user to replace battery. Too short battery life can cause damage to the meter because of battery leakage. This meter has designed standby life of about two years, but we suggest customer to replace a battery each year, and check battery electrodes if there is any rust. Battery should be removed if not usi1The flowmeter control panel adopts modular design, multiple measurement units conversion, complete functions, convenient operation and simple structure.2It can be used to measure methanol, kerosene, diesel, fuel, urea water. It is widely used in petroleum, chemical, pharmaceutical, transportation, food and other industries and commercial fields.3Digital LCD display, high?definition display shows instantaneous and cumulative flow and NPT counter.4Clear and accurate measurement, intuitive and clear reading, high reliability, measurement accuracy 1%.54 unit options, liter (L) / gallon (GAL) / pint (PTS) / quart (QTS), used in different countries. Easy to clean, install and maintain.1. This product requires 2 x AAA batteries, more convenient for you to use, and comes with 2 x AAA batteries replaceable batteries2. Hint of insufficient battery power: LBAT is displayed when the battery voltage is 2.2V ? 2.4V to remind the user to replace the battery.3. Please note that the new type and old type of this product will be sent randomly, and make sure you will not mind before ordering.1 xFlowMeter1 x Adapter2 x Rubber Seal Ring
  • Fruugo-ID: 421660262-888053296
  • EAN: 6473758201137

Produktsäkerhetsinformation

Se produktsäkerhetsinformationen som är specifik för denna produkt som beskrivs nedan

Följande information tillhandahålls av den oberoende tredjepartsåterförsäljaren som säljer denna produkt.

Produktsäkerhetsetiketter

CE Mark
Säkerhetsvarningar: WARNING: TO AVOID DANGER OF SUFFOCATION, KEEP THIS PLASTIC BAG AWAY FROM BABIES AND CHILDREN.

Leverans och returer

Skickas inom 24 timmar

  • STANDARD: GRATIS - Leverans mellan kl fre 17 oktober 2025–mån 27 oktober 2025 - GRATIS

Leverans från Kina.

Vi gör vårt bästa för att säkerställa att produkterna du beställer levereras kompletta och enligt dina specifikationer. Om du däremot skulle ta emot en ofullständig beställning, eller andra artiklar än de du beställt, eller om det finns någon annan anledning till att du inte är nöjd med din beställning, kan du returnera beställningen, eller valfria produkter som ingår i beställningen, och få fullständig ersättning för artiklarna. Visa fullständig returpolicy

Produktöverensstämmelsedetaljer

Vänligen se överensstämmelseinformationen som är specifik för denna produkt som beskrivs nedan.

Följande information tillhandahålls av den oberoende tredjepartsåterförsäljaren som säljer denna produkt.

Tillverkare:
Följande information beskriver kontaktuppgifter för tillverkaren av denna produkt som säljs på Fruugo.

  • CREA
  • CREA
  • 1-3 Boulevard Charles de Gaulle Colombes 92700 FR
  • Colombes
  • FR
  • 92700
  • xmchymx@outlook.com
  • 86-13312976782
  • https://www.fruugo.co.uk/huizhou-yuhengda-trading/m-14512

Ansvarig person i EU:
Följande information innehåller kontaktuppgifter för den ansvariga personen i EU. Den ansvariga personen är den utsedda ekonomiska aktör i EU som ansvarar för att skyldigheterna uppfylls för denna produkt som säljs till Europeiska unionen.

  • E-CrossStu GmbH
  • E-CrossStu GmbH
  • Mainzer Landstr.69,60329 Frankfurt am Main,Hessen, Deutschland
  • Frankfurt am Main
  • DE
  • 60329
  • E-CrossStu@web.de
  • +4969330000000
  • https://www.fruugo.co.uk/huizhou-yuhengda-trading/m-14512