ZKU15 Voltage Current Testing Meter LCD Digital Display Multifunctional Volt Ammeter

119,00 kr
+ 114,49 kr Leverans

ZKU15 Voltage Current Testing Meter LCD Digital Display Multifunctional Volt Ammeter

  • Märke: Unbranded
Säljs av:

ZKU15 Voltage Current Testing Meter LCD Digital Display Multifunctional Volt Ammeter

  • Märke: Unbranded

119,00 kr

Spara 60,00 kr (33%)

RRP

179,00 kr
I lager
+ 114,49 kr Leverans
Säljs av:

119,00 kr

Spara 60,00 kr (33%)

RRP

179,00 kr
I lager
+ 114,49 kr Leverans

Vi erbjuder följande betalsätt

Beskrivning

Condition: 100% Brand New <br>Item Type: Multifunction Volt-Ammeter <br>Material: Plastic Housing <br> <br>Product Size: Approx. 79 x 42 x 26mm/3.1 x 1.7 x 1in <br>ModelZK-U15 <br>Input VoltageDC 5V-38V(With Anti-Reverse Connection) <br>Input Current0.03A-5.00A <br>Operating Current<=30mA <br>Voltage Accuracy(±1%+1 Word) <br>Accuracy of Current(±1%+1 Word) <br>Working Environment Temperature-15℃-50℃ <br>LVP Threshold of Undervoltage Protection4.8V by Default (Adjustable between 4.8V-38V) <br>OVP Threshold for Overvoltage ProtectionDefault 38.0V(Adjustable between 4.8V-38.0V) <br>OCP Threshold for Overcurrent ProtectionDefault 5.5A (Adjustable between 0.5A-5.5A) <br>OTP Threshold of Overtemperature Protection80℃(Adjustable between 40℃-80℃) <br>OCP Threshold for Overcurrent ProtectionDefault 5.5A (Adjustable between 0.5A-5.5A) <br>OPP Threshold of Overpower ProtectionDefault 200W(Adjustable between 1W-200W) <br> <br> <br>Detailed Product Function: <br>1. LCD screen display <br>In the normal mode, the LCD screen displays the input voltage and working temperature in the upper; the lower displays the real-time current, power, capacity and discharge time. In the protection mode, the LCD screen displays the protection codes. <br>In the setting mode, the LCD screen displays each setting parameter codes and parameter threshold. <br>2. Sound and light alarm <br>When the voltage and current meter output is turned on, the RUN indicator light is always on and the buzzer does not sound; when it is turned off, the RUN indicator light does not light, and the buzzer does not sound. After entering the protection mode, the buzzer will alarm and the RUN indicator will flash. <br>3. Automatic statistics of charge and discharge capacity and time. As long as the output is turned on (the RUN indicator is always on), the statistics will be started, and the output will be turned off (the RUN indicator is not on), and the statistics will be stopped. In the interface, long press the button-the corresponding data can be cleared. Start <br>Before statistics, please clear the statistics data to 0. The maximum discharge capacity (OAH) and maximum discharge time (OHP) can be set on or off in the setting mode (default off). After being turned on, the threshold value can be set. If the threshold value is exceeded, the output will be automatically turned off and the buzzer will alarm to achieve no Charging and discharging the battery on duty. <br>4. By setting appropriate over-voltage protection threshold and under-voltage protection threshold, battery overcharge and overdischarge control can be achieved. For detailed operation, please refer to the product application example. <br>5. Complete software and hardware protection mechanism, and the software protection threshold can be adjusted. After software protection, the output is turned off. <br> <br>Hardware Protection: <br>The input port of the module has anti-reverse connection protection, and the reverse connection will not burn. <br> <br>Software Protection: <br>OVP overvoltage protection (default 38V, can be set by yourself, after overvoltage protection, the RUN indicator flashes, and the LCD interface displays OVP. During battery charging, setting a proper threshold can effectively prevent battery overcharging); <br>OCP overcurrent protection (default 5.5A, can be set by yourself, after overcurrent protection, the RUN indicator flashes, and the LCD displays OCP); <br>OPP over power protection (default 200W, can be set by yourself, after over power protection, RUN indicator flashes, LCD shows OPP); <br> <br> <br>Steps for Usage: <br>1. First connect the battery and load, and check whether the wiring is correct. <br>2. The voltage and current meter enters the normal interface. If it is not in the normal interface, short press the ON button to return to the normal inte
  • Märke: Unbranded
  • Kategori: Hygrometrar
  • Bredd: 5
  • Vikt: 0.5
  • Längd: 10
  • Höjd: 5
  • Fruugo-ID: 348696136-761106664
  • EAN: 4853222497129

Produktsäkerhetsinformation

Se produktsäkerhetsinformationen som är specifik för denna produkt som beskrivs nedan

Följande information tillhandahålls av den oberoende tredjepartsåterförsäljaren som säljer denna produkt.

Produktsäkerhetsetiketter

CE Mark

Leverans och returer

Skickas inom 24 timmar

  • STANDARD: 114,49 kr - Leverans mellan kl fre 07 november 2025–fre 14 november 2025

Leverans från Kina.

Vi gör vårt bästa för att säkerställa att produkterna du beställer levereras kompletta och enligt dina specifikationer. Om du däremot skulle ta emot en ofullständig beställning, eller andra artiklar än de du beställt, eller om det finns någon annan anledning till att du inte är nöjd med din beställning, kan du returnera beställningen, eller valfria produkter som ingår i beställningen, och få fullständig ersättning för artiklarna. Visa fullständig returpolicy

Produktöverensstämmelsedetaljer

Vänligen se överensstämmelseinformationen som är specifik för denna produkt som beskrivs nedan.

Följande information tillhandahålls av den oberoende tredjepartsåterförsäljaren som säljer denna produkt.

Tillverkare:
Följande information beskriver kontaktuppgifter för tillverkaren av denna produkt som säljs på Fruugo.

  • Shenzhenyuandedianziyuouxiangongsi
  • Shenzhenyuandedianziyuouxiangongsi
  • Room 903, Building B, Nanxian Commercial Plaza, Nanyuan New Village
  • Hongshan Community, Minzhi Subdistrict, Longhua District
  • Longhua
  • Shenzhen
  • China
  • 518500
  • szrhkj21@163.com
  • 15819859068

Ansvarig person i EU:
Följande information innehåller kontaktuppgifter för den ansvariga personen i EU. Den ansvariga personen är den utsedda ekonomiska aktör i EU som ansvarar för att skyldigheterna uppfylls för denna produkt som säljs till Europeiska unionen.

  • Huang Pengliang
  • FORCHAIN GmbH
  • Vilbeler Landstra?e73 60388 Frankfurt am Main
  • Frankfurt am Main
  • Frankfurt am Main
  • DE
  • 60388
  • nnicolesusan093@gmail.com
  • 1638127736